When the product is just turned on, the product runs away. The reasons for the lack of glue after a
Announcer:Huihong Addtime:2020-02-18
Solution: The melt in the injection tube of the injection molding machine has a long heating time, low melt viscosity, and good fluidity when the machine is just turned on. The product is easy to run, and after a period of production, the melt continuously removes the heat, causing the melt. Insufficient, high viscosity, poor fluidity, making the product lack of glue.
After a period of production, gradually increase the temperature of the tube to solve.
After a period of production, gradually increase the temperature of the tube to solve.